BMYTZ - 200HA SYSTEM, KNIGHT/LAGGI TAPE-PRIMER-CEME
- MSDS: BMYTZ
- Manufacturer: RUSTOL CHEMICALS CO LTD
- Product Name: 200HA SYSTEM, KNIGHT/LAGGI TAPE-PRIMER-CEME
- National Stock Number: 8030-00N029240
Product Identification
Product ID:200HA SYSTEM, KNIGHT/LAGGI TAPE-PRIMER-CEME
MSDS Date:11/06/1989
FSC:8030
NIIN:00N029240
MSDS Number: BMYTZ
Responsible Party
2-CHOME, CHUO-KU, TOKYO JAPAN 104
Emergency Phone: 415-956-4097
Info Phone: 415-956-4097
Cage: RUSTO
Contractor
Telephone: 415-956-4097
Cage: RUSTO
Ingredients
XYLENE
CAS: 1330-20-7
RTECS: ZE2100000
OSHA PEL 100 PPM;150 PPM STEL
ACGIH TLV: 100 PPM;150 PPM STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
CHROMIC ACID, ZINC SALT; (ZINC CHROMATE)
CAS: 13530-65-9
RTECS: GB3290000
OSHA PEL 0.1 MG/M3 (CRO*3)
ACGIH TLV: 0.01 MG/M3 (CR)
CONCERN LATEST HAZ LIST INFO AND SAFE HANDLING
RTECS: 9999999ZZ
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:LD50:(ORAL,RAT) >5 G/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: IRRIT. REDDENING CAN OCCUR W/IN
ONE HR. PERSONS HAVING EYE CONT CAN EXPECT TRANSIENT IRRIT,NOT PERM
DMG.SKIN: READILY ABSORBED THRU SKIN.PRLNGD SKIN CONT RSLT IN IRRIT
& DERMAT.INHAL: RECOMMENDED EXPOS LIMIT TO VAPS: 100 TWA/150 PPM
STE. VAPS MAY CAUSE IRRIT OF THE RESP SYS AND NERV SYS
IMPAIRMENT.(EFTS OF OVEREXP
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:PRLNGED BRTHG OF VAP,SKIN CONT/ INGEST
MAY CAUSE IRRIT.SYMP OF OVEREXP MAY INCLUDE DIZZ,NAUS,HDCHE,VOMIT,
UNCOORD,CONFUSN,DROWS & UNCON.INGEST:CEMENT & PRIMER ARE SLIGHTLY
TOX UPON INGEST.NOT E:TOLUENE,CAS#108-88-3,APPEARS ON NAVY LISTING
OF OCCUP REPRO HAZ.SEEK CONSULTATION FROM APPROP
HEALTHPROFESSIONALS(ING
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. CALL MD.
SKIN: USE HAND CLEANER AND FOLLOW WITH A GOOD WASHING WITH SOAP AND
WATER. INHAL: REMOVE TO FRESH AIR. INGEST: CALL MD IMMEDIATELY.
Fire Fighting
Flash Point:176F,80C
Lower Limits:0.9%
Upper Limits:7%
Extinguishing Media:WATER, FOAM, CO2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.
Accidental Release
Spill Release Procedures:COLLECT SPILLED MATERIAL USING AN ABSORBENT
AND PLACE IN A DOT APPROVED CONTAINER FOR SHIPMENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS & OPEN
FLAME. AVOID EYE CONTACT. AVOID PROLONGED BREATHING OF VAPORS. KEEP
CONTAINERS CLOSED WHEN NOT IN USE.
Other Precautions:USE ONLY IN WELL VENTILATED AREAS WITH SUFFICIENT AIR
MOVEMENT TO MAINTAIN VAPOR LEVELS AT RECOGNIZED HEALTH & SAFETY
LEVELS. GLYCOL ETHERS MAY BE REPRO TOXICANTS. AVOID USE OF PRODS
DURING PREGNANCY. WHILE HEATING KNIGHT 200HA (SUPP DATA)
Exposure Controls
Respiratory Protection:IN CONFINED AREAS OR POORLY VENTILATED AREAS,
USE A NIOSH/MSHA APPROVED HALF MASK RESPIRATOR EQUIPPED WITH
ORGANIC VAPOR CARTRIDGES.
Ventilation:USE OUTDOORS OR IN WELL VENTILATED AREAS. LOCAL EXHAUST
SHOULD BE GREATER THAN 60 FPM.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
WASTE DISP PROC: UNUSED MATL CAN BE DISPOSED OF IN A SIMILAR MANNER OR
INCINERATED AT A PERMITTED HAZ WASTE FACILITY. DISPOSAL MUST BE IN
ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGS . OTHER PR EC: OR
200HB DURING THE APPLICATION STEP, BE SURE TO USE RECOMMENDED
PERSONAL PROT EQUIPMENT.
Chemical Properties
HCC:V4
Vapor Pres:<20
Vapor Density:3.8
Spec Gravity:1.6
Evaporation Rate & Reference:<0.6
Solubility in Water:NEGLIGIBLE
Appearance and Odor:ESTER/SOLVENT ODOR.
Percent Volatiles by Volume:30
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS.
Stability Condition to Avoid:SPARKS, OPEN FLAME.
Hazardous Decomposition Products:CO, ALDEHYDES, NOXIOUS FUMES.
Disposal
Waste Disposal Methods:THE KNIGHT/LAGGI SYSTEMS MUST BE DISPOSED OF AS
RCRA HAZ WASTE EPA HAZ WASTE NUMBER D001.PROPER SHIPPING NAME TO BE
USED IS "HAZ WASTE SOLID ORME". BE SURE CONTENTS ARE SOLID BY USING
SUFF ABSORB. LIQ SHOULD NOT EXCEED 20% OF TOTAL VOLUME.(SUPP DATA)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.